Concrete block units shall conform to astm c90.
City of los angeles standard retaining wall detail.
Each series contains several standard plans.
County of los angeles department of public works building and safety division based on the 2011 lacrc 1014 r404 4 article 1 10 25 12 page 1 of 7 design of retaining walls issue.
The height of a retaining wall is measured from grade on the lower side of the retaining wall to the top of the retaining wall exposed height e sdmc 113 0270 b 2.
Disabled access standard details notes for commercial buildings.
Reinforcing steel shall be deformed steel conforming to a s t m.
City of los angeles electrical plan check correction list.
Multiple cover details for sanitary sewer manholes.
San diego municipal code chapter 14 article 2.
Design of retaining walls as presented in this bulletin are in accordance with sections 1610 1 and 1807 2 of the city of los angeles building code labc.
213 847 0700.
Plumbing plan check correction list for 2017 codes 422 kb view.
Back to standard plans main index.
Informational page for pre approved standard plans.
Page 1 of 2 retaining or slough wall 4 0 high or less.
6 concrete block masonry wall detail 6 0 height maximum general specifications.
Soil lateral loads labc 1610 1 general.
Concrete block units to be standard 8 x8 x16 units conforming to ubc standard 21 4.
Alternative design procedures justified in a geotechnical report may also be approved.
Concrete block units to have vertical continuity of the cells unobstructed.
Retaining or slough wall 4 foot high or less 178 kb view.
Residential code section r404 4 specifies that retaining walls shall be designed to ensure.
The standard plans are divided into several series.
1149 s broadway suite b 10 los angeles ca 90015 phone.
Retaining walls heights are also regulated by the zoning laws of the city as follows.
Concrete block retaining wall h 6 0 max b3761 1 b3761 2.
If any information on any of the standard plans is not legible it is the user s responsibility to obtain a legible copy from the bureau of engineering vault located at.
Metal bin type retaining wall.
As a covered entity under title ii of the americans with disabilities act the city of los angeles does not discriminate on the basis of disability and upon request will provide reasonable accommodation to ensure equal access to its programs services and activities.
Concrete mix for footing to be 1 part cement to 2 5 parts sand to 3 5 parts gravel with a maximum of 7 5 gallons of water per sack of cement minimum f c 2 500 psi.
Concrete block units to be staggered running bond.
Lap all steel 16.